Tandberg Data DPS Expansion Module Disk Pack Specifikace Strana 64

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 63
58 |
Alarms
DPS Expansion Module has visual and audible alarms that alert you to the status of the
system.
Visible alarms
The functional modules have associated status LEDs. The OPS panel shows a consolidated
status for all identified modules.
Audible alarms
DPS Expansion Module includes an audible alarm that indicates when a fault state is
present. The following conditions will activate the audible alarm:
•Fan fault
Voltage out of range
Over temperature
Thermal overrun
System fault
Logical fault
Power supply fault
Removal of one power supply module
To mute an audible alarm, press the Alarm Mute button on the enclosure front panel. The
alarm will be muted automatically after two minutes if the mute switch is not manually
operated.
The alarm sounds continuously for critical error conditions such as when the enclosure
temperature has exceeded the upper limit, more than one fan fails, or the controller
temperature fails. You cannot mute these alarms.
LED State Description
Power On Steady Green Power applied to the enclosure.
System Fault Steady Amber Indicates a problem with a Power Supply or Cooling
Fan module. For specific fault LEDs per module, see
Power supply module LEDs on page 53 and Cooling fan
module LED on page 54.
Logical Fault Steady Amber Indicates failure of a disk drive in an array. The LED
will remain illuminated until the array is fault tolerant.
Disk drives not part of an array will not illuminate the
Logical Fault LED. See OPS panel LEDs on page 54.
Logical Fault LED will illuminate when a RAID
Controller fault occurs.
Box Identity Blinking Blue You can illuminate this LED from the DPS Expansion
Module interface to identify an enclosure.